Amplified Low Pressure Sensors
1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors
Military Temperature Grade
Features
all sensors
• 0 to 1 mbar to 0 to 30 In H2O Pressure Ranges
• Ratiometric 4V Output
• Temperature Compensated (-40C to 125C)
• Calibrated Zero and Span
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or
common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics.
Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position
sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the
sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output
e www.allsensors.com
General Description
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
Physical Dimensions
0.25
(6.4)
Pin Size
0.010 x 0.020
(0.25 x 0.50)
0.10 Typical
(2.54)
Pin 1 2 3 4
0.174 to 0.190
(4.4 to 4.8)
pin 1: Vsupply
0.21
(5.3)
1
pin 2: Common
pin 3: Voutput
A
1.08
(27.4)
0.66
(16.0)
0.48
(12.2)
0.55
(14.0)
NOTES:
1) Dimensions in inches (millimeters)
B
0.80
(20.3)
0.85
(21.6)
1.10
(27.9)
All Sensors
DS-0026 Rev A
0.42
(10.5)
pin 4: do not connect
a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
f 408 225 2079
to measured pressure.
Pressure Sensor Ratings
Environmental Specifications
+4.5 to +5.5 Vdc
Supply Supply Voltage VS
Temperature Ranges
-10 to +10 psig
Common-mode pressure
250°C
Lead Temperature, max
(soldering 2-4 sec.)
Compensated
-40 to 125° C
Operating
-40 to 125° C
Storage
-40 to 125° C
Humidity Limits
0 to 95% RH
(non condensing)
Standard Pressure Ranges
Part Number
Operating Pressure
Nominal Span
Proof Pressure
Burst Pressure
1 MBAR-D-4V-MIL
±1 mbar
4V
100 In H2O
200 In H2O
1 INCH-D-4V-MIL
±1 In H2O
4V
100 In H2O
200 In H2O
1 INCH-G-4V-MIL
0 - 1 In H2O
4V
300 In H2O
200 In H2O
5 INCH-D-4V-MIL
± 5 In H2O
4V
200 In H2O
300 In H2O
5 INCH-G-4V-MIL
0 - 5 In H2O
4V
200 In H2O
300 In H2O
10 INCH-D-4V-MIL
±10 In H2O
4V
200 In H2O
300 In H2O
10 INCH-G-4V-MIL
0 - 10 In H2O
4V
200 In H2O
300 In H2O
20 INCH-D-4V-MIL
±20 In H2O
4V
300 In H2O
500 In H2O
20 INCH-G-4V-MIL
0 - 20 In H2O
4V
300 In H2O
500 In H2O
30 INCH-D-4V-MIL
±30 In H2O
4V
500 In H2O
800 In H2O
30 INCH-G-4V-MIL
0 - 30 In H2O
4V
500 In H2O
800 In H2O
Performance Characteristics for: 1 MBAR-D-4V-MIL
Parameter, NOTE 1
Minimum
Operating Range, differential pressure
Output Span,
NOTE
5
Offset Voltage @ zero differential pressure
Nominal
±1.0
mbar
±2.0
±2.20
volt
2.00
2.25
2.50
volt
±120
mvolt
±20
mvolt
Offset Position Sensitivity (±1g)
±40
mvolt
Offset Long Term Drift (one year)
±20
mvolt
Linearity, hysteresis error, NOTE 4
0.05
NOTE
3
Units
±1.80
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift,
Maximum
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±4
%span
Amplified Low Pressure Sensors Military Grade
Performance Characteristics for 1 INCH-D-4V-MIL
Minimum
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Nominal
Maximum
±1.0
Units
“H2O
±1.90
±2.0
±2.10
volt
2.15
2.25
2.35
volt
±60
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±10
mvolt
±5
mvolt
Offset Long Term Drift (one year)
±10
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Offset Position Sensitivity (±1g)
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±2
%span
Maximum
Units
all sensors
Parameter, note 1
Operating Range, gage pressure
Nominal
1.0
“H2O
Output Span, note 5
3.90
4.0
4.10
volt
Offset Voltage @ zero pressure
0.15
0.25
0.35
volt
±60
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±10
mvolt
Offset Position Sensitivity (±1g)
±15
mvolt
Offset Long Term Drift (one year)
±10
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±2
%span
Maximum
Units
Performance Characteristics for 5 INCH-D-4V-MIL
Parameter, note 1
Minimum
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Nominal
±5.0
“H2O
±1.90
±2.0
±2.10
volt
2.15
2.25
2.35
volt
±40
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
All Sensors
DS-0026 Rev A
0.25
%fs
±1
%span
f 408 225 2079
Minimum
a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314
Parameter, note 1
e www.allsensors.com
Performance Characteristics for 1 INCH-G-4V-MIL
Performance Characteristics for: 5 INCH-G-4V-MIL
Parameter, NOTE 1
Minimum
Nominal
Operating Range, gage pressure
Output Span,
NOTE
5
Offset Voltage @ zero pressure
Maximum
5.0
Units
“H2O
3.90
4.0
4.10
volt
0.15
0.25
0.35
volt
±40
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±1
%span
Maximum
Units
Performance Characteristics for: 10 INCH-D-4V-MIL
Parameter, NOTE 1
Minimum
Nominal
Operating Range, differential pressure
Output Span, NOTE 5
Offset Voltage @ zero differential pressure
±10.0
“H2O
±1.90
±2.0
±2.10
volt
2.15
2.25
2.35
volt
±20
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±1
%span
Maximum
Units
Performance Characteristics for: 10 INCH-G-4V-MIL
Parameter, NOTE 1
Minimum
Operating Range, gage pressure
Output Span,
NOTE
5
Offset Voltage @ zero pressure
Nominal
10.0
“H2O
3.90
4.0
4.10
volt
0.15
0.25
0.35
volt
±20
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±1
%span
Amplified Low Pressure Sensors Military Grade
Performance Characteristics for 20 INCH-D-4V-MIL
Offset Voltage @ zero differential pressure
±20.0
Units
“H2O
±1.90
±2.0
±2.10
volt
2.15
2.25
2.35
volt
±20
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±1
%span
Maximum
Units
Performance Characteristics for 20 INCH-G-4V-MIL
Parameter, note 1
Minimum
Operating Range, gage pressure
Nominal
20.0
“H2O
Output Span, note 5
3.90
4.0
4.1
volt
Offset Voltage @ zero pressure
0.15
0.25
0.35
volt
±20
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±1
%span
Maximum
Units
Performance Characteristics for 30 INCH-D-4V-MIL
Parameter, note 1
Minimum
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Nominal
±30.0
“H2O
±1.90
±2.0
±2.10
volt
2.15
2.25
2.35
volt
±20
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
All Sensors
DS-0026 Rev A
0.25
%fs
±1
%span
all sensors
Output Span, note 5
Maximum
e www.allsensors.com
Operating Range, differential pressure
Nominal
f 408 225 2079
Minimum
a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314
Parameter, note 1
Performance Characteristics for 30 INCH-G-4V-MIL
Parameter, NOTE 1
Minimum
Operating Range, gage pressure
Output Span,
NOTE
5
Offset Voltage @ zero pressure
Nominal
Maximum
30.0
Units
“H2O
3.9
4.0
4.1
volt
0.15
0.25
0.35
volt
±20
mvolt
Offset Temperature Shift (-40°C-125°C), NOTE 2
Offset Warm-up Shift, NOTE 3
±5
mvolt
Offset Position Sensitivity (±1g)
±5
mvolt
Offset Long Term Drift (one year)
±5
mvolt
Linearity, hysteresis error, NOTE 4
0.05
Span Shift (-40°C-125°C), NOTE 2
0.25
%fs
±1
%span
Equivalent Circuit
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 500 useconds.
Specification Notes
NOTE
1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
OTHERWISE SPECIFIED.
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
2:
NOTE 3:
NOTE 4:
NOTE 5:
SHIFT IS RELATIVE TO 25°C.
SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS
FOR MINUS TO PLUS FULL SCALE PRESSURE.
NOTE
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
Amplified Low Pressure Sensors Military Grade